Improve gas_ceiling scaling
Represent int kΩ rather than raw Ω for easier values.
This commit is contained in:
12
README.md
12
README.md
@ -63,13 +63,15 @@ but can be done if desired.
|
||||
|
||||
The AQ (air quality) calculation from the BME680 requires a "maximum"/ceiling
|
||||
threshold for the gas resistance value in clean air after some operation
|
||||
time. The value defaults to 200,000 to provide an initial baseline, but
|
||||
should be calibrated manually by:
|
||||
time. The value defaults to 200 kΩ to provide an initial baseline, but
|
||||
should be calibrated manually after setup as each sensor is different:
|
||||
|
||||
1. Turning on the Supersensor in a known-clean environment (e.g. a sealed
|
||||
1. Turn on the Supersensor in a known-clean environment (e.g. a sealed clean
|
||||
container in fresh air).
|
||||
2. Leave the sensor on for 4-6 hours to burn in the sensor.
|
||||
3. Setting this to the maximum value of the Gas Resistance sensor.
|
||||
2. Leave the sensor on for 4-6 hours to burn in.
|
||||
3. Record the maximum Gas Resistance value (in Ω) and round up to the nearest
|
||||
5,000-10,000 or so (e.g. 96,938 => 100,000).
|
||||
4. Divide the rounded maximum Gas Resistance value by 1000 to get the kΩ value.
|
||||
|
||||
This value will then define what "100% air quality" represents, and the
|
||||
Supersensor can then be moved to its normal operating location.
|
||||
|