Add customizable room health options and tweak
Permits the user customization of the parameters of the Room Health Score, enabling fine-grained control over this metric instead of hardcoding values that may not be suitable for each person or room.
This commit is contained in:
308
README.md
308
README.md
@@ -118,144 +118,7 @@ functionality, so I recommend using the provided models, but this is up to the b
|
||||
|
||||
No other parts can be easily swapped without code or PCB design changes.
|
||||
|
||||
## Configurable Options
|
||||
|
||||
There are several UI-configurable options with the SuperSensor to help you
|
||||
get the most out of the sensor for your particular use-case.
|
||||
|
||||
**Note:** Configuration of the LD2410C is excluded here, as it is extensively
|
||||
configurable. See [the documentation](https://esphome.io/components/sensor/ld2410.html) for more details on its options.
|
||||
|
||||
### Enable Voice Support (switch)
|
||||
|
||||
If enabled (the default), the SuperSensor's voice functionality including
|
||||
wake word will be started, or it can be disabled to use the SuperSensor
|
||||
purely as a presence/environmental sensor.
|
||||
|
||||
### Enable Presence LED (switch)
|
||||
|
||||
If enabled (the default), when overall presence is detected, the LEDs will
|
||||
glow "white" at 15% power to signal presence.
|
||||
|
||||
### Temperature Offset (selector, -30 to +10 @ 0.1, -5 default)
|
||||
|
||||
Allows calibration of the SHT45 temperature sensor with an offset from -30 to +10
|
||||
degrees C. Useful if the sensor is misreporting actual ambient tempreatures. Due
|
||||
to internal heating of the SHT45 by the ESP32, this defaults to -5; further
|
||||
calibration may be needed for your sensors and environment based on an external
|
||||
reference.
|
||||
|
||||
### Humidity Offset (selector, -20 to +20 @ 0.1)
|
||||
|
||||
Allows calibration of the SHT45 humidity sensor with an offset from -10 to +10
|
||||
percent relative humidity. Useful if the sensor is misreporting actual humidity
|
||||
based on an external reference.
|
||||
|
||||
### PIR Hold Time (selector, 0 to +60 @ 5, 0 default)
|
||||
|
||||
The SuperSensor uses an AM312 PIR sensor, which has a stock hold time of ~2.5
|
||||
seconds. This setting allows increasing that value, with retrigger support, to
|
||||
up to 60 seconds, allowing the PIR detection to report for longer. 0 represents
|
||||
"as long as the AM312 fires".
|
||||
|
||||
### Light Threshold Control (selector, 0 to +200 @ 5, 30 default)
|
||||
|
||||
The SuperSensor features a "light presence" binary sensor based on the light
|
||||
level reported by the TSL2591 sensor. This control defines the minimum lux
|
||||
value from the sensor to be considered "presence". For instance, if you have
|
||||
a room that is usually dark at 0-5 lux, but illuminated to 100 lux when a
|
||||
(non-automated) light switch is turned on, you could set a threshold here
|
||||
of say 30 lux: then, while the light is on, "light presence" is detected,
|
||||
and when the light is off, "light presence" is cleared. Light presence can
|
||||
be used standalone or as part of the integrated occupancy sensor (below).
|
||||
|
||||
### Integrated Occupancy Sensor (Selector)
|
||||
|
||||
The SuperSensor features a fully integrated "occupancy" sensor, which can be
|
||||
configured to provide exactly the sort of occupancy detection you may want
|
||||
for your room.
|
||||
|
||||
There are 7 options (plus "None"/disabled), with both "detect" and "clear"
|
||||
handled separately:
|
||||
|
||||
#### PIR + Radar + Light
|
||||
|
||||
Occupancy is detected when all 3 sensors report detected, and occupancy is
|
||||
cleared when any of the sensors report cleared.
|
||||
|
||||
For detect, this provides the most "safety" against misfires, but requires
|
||||
a normally-dark room with a non-automated light source and clear PIR
|
||||
detection positioning.
|
||||
|
||||
For clear, this option is probably not very useful as it is likely to clear
|
||||
quite frequently from the PIR, but is provided for completeness.
|
||||
|
||||
#### PIR + Radar
|
||||
|
||||
Occupancy is detected when both sensors report detected, and occupancy is
|
||||
cleared when either of the sensors report cleared.
|
||||
|
||||
For detect, this provides good "safety" against PIR misfires without
|
||||
needing a normally-dark room, though detection may be slightly delayed
|
||||
from either sensor.
|
||||
|
||||
For clear, this option is probably not very useful as it is likely to clear
|
||||
quite frequently from the PIR, but is provided for completeness.
|
||||
|
||||
#### PIR + Light
|
||||
|
||||
Occupancy is detected when both sensors report detected, and occupancy is
|
||||
cleared when either of the sensors report cleared.
|
||||
|
||||
For detect, this provides some "safety" against PIR misfires, but requires
|
||||
a normally-dark room with a non-automated light source and clear PIR
|
||||
detection positioning.
|
||||
|
||||
For clear, this option is probably not very useful as it is likely to clear
|
||||
quite frequently from the PIR, but is provided for completeness.
|
||||
|
||||
#### Radar + Light
|
||||
|
||||
Occupancy is detected when both sensors report detected, and occupancy is
|
||||
cleared when either of the sensors report cleared.
|
||||
|
||||
For detect, this allows for radar detection while suppressing occupancy
|
||||
without light, for instance in a hallway where one might not want a late
|
||||
night bathroom visit to turn on the lights, or something to that effect.
|
||||
|
||||
For clear, this option can provide a useful option to clear presence
|
||||
quickly if the lights go out, while still providing Radar presence.
|
||||
|
||||
#### PIR Only
|
||||
|
||||
Occupancy is based entirely on the PIR sensor for both detect and clear.
|
||||
|
||||
Prone to misfires, but otherwise a good option for quick detection and
|
||||
clearance in a primarily-moving zone (e.g. hallway).
|
||||
|
||||
#### Radar Only
|
||||
|
||||
Occupancy is based entirely on the Radar sensor for both detect and clear.
|
||||
|
||||
Useful for an area with no consistent motion or light level.
|
||||
|
||||
#### Light Only
|
||||
|
||||
Occupancy is based entirely on the Light sensor for both detect and clear.
|
||||
|
||||
Useful for full dependence on an external light source.
|
||||
|
||||
#### None
|
||||
|
||||
Disable the functionality in either direction.
|
||||
|
||||
For detect, no occupancy will ever fire.
|
||||
|
||||
For clear, no states will clear occupancy; with any detect option, this
|
||||
means that occupancy will be detected only once and never clear, which
|
||||
is likely not useful.
|
||||
|
||||
## AQ Details
|
||||
## Air Quality Handling
|
||||
|
||||
The SuperSensor 2.0 features an SGP41 air quality sensor by Sensirion. This is a powerful AQ
|
||||
sensor which powers several commercial devices including the AirGradient One, which gave
|
||||
@@ -283,3 +146,172 @@ It also reacts strongly to heavy humidity, resulting in higher values in such en
|
||||
These should be used only as a general indication of air quality over short periods, rather
|
||||
than an absolute reference over long periods (much to my own frustration but inevitable
|
||||
begruding acceptance).
|
||||
|
||||
## Room Health
|
||||
|
||||
The SuperSensor 2.0 leverages the outputs of the SHT45 and SGP41 sensors to calculate a
|
||||
"Room Health", expressed as a percentage, which represents how "healthy" i.e. comfortable
|
||||
a room is for a person to be in.
|
||||
|
||||
The room health is calculated based on the VOC level, temperature, and relative humidity.
|
||||
First, the raw value is converted to a per-sensor 100-0 scale as follows:
|
||||
|
||||
* For VOC levels, there is a set of linear scales based on common VOC level
|
||||
mappings, such that less than 200 ppb is 100, 200-400 maps to 100-90,
|
||||
400-600 maps to 90-70, 600-1500 maps to 70-40, 1500-3000 maps to 40-0, and
|
||||
greater than 3000 is 0.
|
||||
* For temperature and humidity, there is a single linear scale based on a
|
||||
configurable penalty value, such that a value between the configurable
|
||||
minimum and maximum is 100, and each degree C or %RH outside of that range
|
||||
decreases the value by the penalty value.
|
||||
|
||||
Next, each indivdual per-sensor value is applied to the total 100-0 value by a configurable
|
||||
weight, with the defaults being 40% to VOC level, 30% to temperature, and 30% to humidity. The
|
||||
values can never total more than 100% or total to 0% but are otherwise normalized (i.e. decrease
|
||||
others before increasing one, or the values will not be accepted; and at least one weight
|
||||
must be >0).
|
||||
|
||||
The final result is thus a 100-0% range that, in broad strokes, describes the overall
|
||||
health of the room. For some examples, assuming all of the default values below:
|
||||
|
||||
* Perfect: Temp 23C, humidity 50%RH, and VOC level 150ppb = 100% health
|
||||
* A little warm: Temp 25C (+1), humidity 50%RH, and VOC level 250ppb = 97% health
|
||||
* Dry: Temp 22C, humidity 30%RH (-10), VOC level 150ppb = 91% health
|
||||
* Dirty air: Temp 23C, humidity 50%RH, VOC level 800ppb = 85% health
|
||||
* Hot & humid: Temp 28C, humidity 70%RH, VOC level 250ppb = 84% health
|
||||
* All-around bad: Temp 30C, humidity 30%RH, VOC level 2000ppb = 52% health
|
||||
|
||||
These are then mapped to textual values as well with the following bands:
|
||||
|
||||
* 100%-95%: Great
|
||||
* 95%-90%: Good
|
||||
* 90%-80%: Fair
|
||||
* 80%-60%: Poor
|
||||
* 60%-0%: Bad
|
||||
|
||||
As mentioned above, most portions of this are configurable; see the section below for
|
||||
specific details of each configuration value.
|
||||
|
||||
## Configurable Options
|
||||
|
||||
There are several UI-configurable options with the SuperSensor to help you
|
||||
get the most out of the sensor for your particular use-case.
|
||||
|
||||
**Note:** Configuration of the LD2410C is excluded here, as it is extensively
|
||||
configurable. See [the documentation](https://esphome.io/components/sensor/ld2410.html) for more details on its options.
|
||||
|
||||
### Enable Voice Support (switch)
|
||||
|
||||
If enabled (the default), the SuperSensor's voice functionality including
|
||||
wake word will be started, or it can be disabled to use the SuperSensor
|
||||
purely as a presence/environmental sensor.
|
||||
|
||||
### Enable Presence LED (switch)
|
||||
|
||||
If enabled (the default), when overall presence is detected, the LEDs will
|
||||
glow "white" at 15% power to signal presence.
|
||||
|
||||
### Temperature Offset (number, -30 to +10 @ 0.1, -5 default)
|
||||
|
||||
Allows calibration of the SHT45 temperature sensor with an offset from -30 to +10
|
||||
degrees C. Useful if the sensor is misreporting actual ambient tempreatures. Due
|
||||
to internal heating of the SHT45 by the ESP32, this defaults to -5; further
|
||||
calibration may be needed for your sensors and environment based on an external
|
||||
reference.
|
||||
|
||||
### Humidity Offset (number, -20 to +20 @ 0.1)
|
||||
|
||||
Allows calibration of the SHT45 humidity sensor with an offset from -10 to +10
|
||||
percent relative humidity. Useful if the sensor is misreporting actual humidity
|
||||
based on an external reference.
|
||||
|
||||
### PIR Hold Time (number, 0 to +60 @ 5, 0 default)
|
||||
|
||||
The SuperSensor uses an AM312 PIR sensor, which has a stock hold time of ~2.5
|
||||
seconds. This setting allows increasing that value, with retrigger support, to
|
||||
up to 60 seconds, allowing the PIR detection to report for longer. 0 represents
|
||||
"as long as the AM312 fires".
|
||||
|
||||
### Light Threshold Control (number, 0 to +200 @ 5, 30 default)
|
||||
|
||||
The SuperSensor features a "light presence" binary sensor based on the light
|
||||
level reported by the TSL2591 sensor. This control defines the minimum lux
|
||||
value from the sensor to be considered "presence". For instance, if you have
|
||||
a room that is usually dark at 0-5 lux, but illuminated to 100 lux when a
|
||||
(non-automated) light switch is turned on, you could set a threshold here
|
||||
of say 30 lux: then, while the light is on, "light presence" is detected,
|
||||
and when the light is off, "light presence" is cleared. Light presence can
|
||||
be used standalone or as part of the integrated occupancy sensor (below).
|
||||
|
||||
### Integrated Occupancy Sensor (selector)
|
||||
|
||||
The SuperSensor features a fully integrated "occupancy" sensor, which can be
|
||||
configured to provide exactly the sort of occupancy detection you may want
|
||||
for your room.
|
||||
|
||||
There are 7 options (plus "None"/disabled), with both "detect" and "clear"
|
||||
handled separately. Occupancy is always detected when ALL of the selected
|
||||
sensors report detection, and occupancy is always cleared when ANY of the
|
||||
selected sensors stop reporting detection (logical AND in, logical OR out).
|
||||
|
||||
* PIR + Radar + Light
|
||||
* PIR + Radar
|
||||
* PIR + Light
|
||||
* Radar + Light
|
||||
* PIR Only
|
||||
* Radar Only
|
||||
* Light Only
|
||||
* None
|
||||
|
||||
### Room Health Sensor
|
||||
|
||||
#### Minimum Temperature (number, 15 to 30 @ 0.5, 21 default)
|
||||
|
||||
The lower bounds of a fully comfortable temperature; temperature values below
|
||||
this value will begin decreasing the room health score.
|
||||
|
||||
#### Maximum Temperature (number, 15 to 30 @ 0.5, 24 default)
|
||||
|
||||
The upper bounds of a fully comfortable temperature; temperature values above
|
||||
this value will begin decreasing the room health score.
|
||||
|
||||
#### Temperature Penalty (number, 1 to 20 @ 1, 10 default)
|
||||
|
||||
The penalty value per degree of temperature deviation from ideal levels, applied
|
||||
to the pre-weighting value for temperature.
|
||||
|
||||
#### Minimum Humidity (number, 20 to 80 @ 1, 40 default)
|
||||
|
||||
The lower bounds of a fully comfortable relative humidity level; relative
|
||||
humidity values below this value will begin decreasing the room health score.
|
||||
|
||||
#### Maximum Humidity (number, 20 to 80 @ 1, 60 default)
|
||||
|
||||
The upper bounds of a fully comfortable relative humidity level; relative
|
||||
humidity values above this value will begin decreasing the room health score.
|
||||
|
||||
#### Humidity Penalty (number, 1 to 10 @ 1, 5 default)
|
||||
|
||||
The penalty value per % of relative humidity deviation from ideal levels, applied
|
||||
to the pre-weighting value for humidity.
|
||||
|
||||
#### VOC Weight (number, 0.0 to 1.0, 0.4 default)
|
||||
|
||||
The weighting value of the VOC score relative to the other two for calculating
|
||||
the total room health.
|
||||
|
||||
Note: Cannot exceed 0.4 without first decreasing one of the other weights (total max of 1.0).
|
||||
|
||||
#### Temperature Weight (number, 0.0 to 1.0, 0.3 default)
|
||||
|
||||
The weighting value of the Temperature score relative to the other two for
|
||||
calculating the total room health.
|
||||
|
||||
Note: Cannot exceed 0.3 without first decreasing one of the other weights (total max of 1.0).
|
||||
|
||||
#### Humidity Weight (number, 0.0 to 1.0, 0.3 default)
|
||||
|
||||
The weighting value of the Humidity score relative to the other two for calculating
|
||||
the total room health.
|
||||
|
||||
Note: Cannot exceed 0.3 without first decreasing one of the other weights (total max of 1.0).
|
||||
|